Littelfuse NHB Series Manuale Utente Pagina 1

Navigare online o scaricare Manuale Utente per Hardware Littelfuse NHB Series. Littelfuse NHB Series User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 2
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
Littelfuse.com © 2013 Littelfuse POWR-GARD
®
Products
POWR-GARD
®
Fuse Datasheet
Rev: 013013
1 of 2
NH FUSE LINKS
500 Volts • 2-630 A
Specifications
Voltage Rating 500 VAC
440 VDC
Ampere Range 2-630 A
Interrupting Rating 120 kA AC
25 kA DC
Standards DIN 43.620, IEC 269-2-1
Approvals VDE
Example part number NH1CG25 (size, characteristic and amperage)
Indication All NH fuse links incorporate a
blown fuse indicator
Recommended Fuse Holders
NHB Series Fuse Base
NHF Series Disconnects
Ordering Information
AMPERAGE
gL-gG 500 V ORDERING NUMBER aM 500 V ORDERING NUMBER
NH00C / NH00 NH0 NH1C / NH1 NH2C / NH2 NH3C / NH3 NH00CM NH1 NH2 NH3
2 NH00CG2 NH00CM2
4 NH00CG4 NH00CM4
6 NH00CG6 NH0G6 NH00CM6
10 NH00CG10 NH0G10 NH00CM10
16 NH00CG16 NH0G16 NH00CM16
20 NH00CG20 NH0G20 NH00CM20
25 NH00CG25 NH0G25 NH1CG25 NH00CM25
32 NH00CG32 NH0G32 NH1CG32 NH00CM32
35 NH00CG35 NH0G35 NH1CG35 NH00CM35
40 NH00CG40 NH0G40 NH1CG40 NH2CG40 NH00CM40
50 NH00CG50 NH0G50 NH1CG50 NH2CG50 NH00CM50
63 NH00CG63 NH0G63 NH1CG63 NH2CG63 NH00CM63 NH1M63
80 NH00CG80 NH0G80 NH1CG80 NH2CG80 NH00CM80 NH1M80
100 NH00CG100 NH0G100 NH1CG100 NH2CG100 NH00CM100 NH1M100
125 NH00G125 NH0G125 NH1CG125 NH2CG125 NH1M125 NH2M125
160 NH00G160 NH0G160 NH1CG160 NH2CG160 NH1M160 NH2M160
200 NH1G200 NH2CG200 NH1M200 NH2M200
224 NH1G224 NH2CG224 NH1M224 NH2M224
250 NH1G250 NH2CG250 NH1M250 NH2M250
300 NH2G300 NH2M300
315 NH2G315 NH3CG315 NH2M315 NH3M315
355 NH2G355 NH3CG355 NH2M355 NH3M355
400 NH2G400 NH3CG400 NH2M400 NH3M400
425 NH3G425
500 NH3G500 NH3M500
630 NH3G630 NH3M630
Web Resources
For the latest international fuse products, visit:
Littelfuse.com/nh
Description
Littelfuse
®
European style NH fuse links are designed for the
protection of conductors and motors. The gL-gG characteristic
fuse links are generally used to protect cables and installation
lines from overloads and short-circuits. The aM characteristic
fuse links are used for the short-circuit protection of motors
and switchgear. They are available in NH00C to NH3 sizes
up to 630 A.